Sign In | Join Free | My burrillandco.com
Home > OLT Optical Line Terminal >

Huawei Mpwd Power Board AC 220V Module Embedded Olt Ma5608t

HONGKING INDUSTRIAL CO., LIMITED
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now
    Buy cheap Huawei Mpwd Power Board AC 220V Module Embedded Olt Ma5608t from wholesalers
     
    Buy cheap Huawei Mpwd Power Board AC 220V Module Embedded Olt Ma5608t from wholesalers
    • Buy cheap Huawei Mpwd Power Board AC 220V Module Embedded Olt Ma5608t from wholesalers
    • Buy cheap Huawei Mpwd Power Board AC 220V Module Embedded Olt Ma5608t from wholesalers
    • Buy cheap Huawei Mpwd Power Board AC 220V Module Embedded Olt Ma5608t from wholesalers
    • Buy cheap Huawei Mpwd Power Board AC 220V Module Embedded Olt Ma5608t from wholesalers
    • Buy cheap Huawei Mpwd Power Board AC 220V Module Embedded Olt Ma5608t from wholesalers
    • Buy cheap Huawei Mpwd Power Board AC 220V Module Embedded Olt Ma5608t from wholesalers

    Huawei Mpwd Power Board AC 220V Module Embedded Olt Ma5608t

    Ask Lasest Price
    Supply Ability : 10000pcs/Week
    Payment Terms : T/T,Western Union
    Certification : CE ROHS Anatel
    Price : Negociatable
    Delivery Time : 7-15days
    • Product Details
    • Company Profile

    Huawei Mpwd Power Board AC 220V Module Embedded Olt Ma5608t

    Product Description

    Customer Question & Answer

    Ask something for more details

    H801MPWD-AC power board
    Huawei Mpwd Power Board AC 220V Module Embedded Olt Ma5608t


    The H801MPWD board is an AC power board, consisting of an AC power unit and a monitoring unit. The board supplies power to the device and supports the lead-acid battery for power backup. The AC power unit provides overcurrent protection, output overvoltage protection, short circuit protection, and over-temperature protection. The monitoring unit provides comprehensive management for the power system and storage battery, and also provides certain environment monitoring functions.

    Overview

    The H801MPWD board supports the following functions and specifications:

    • Input AC voltage: -100 V to -240 V
    • Input AC frequency: 50 Hz to 60 Hz
    • Single-phase three-wire AC power input
    • Battery port, a 3V3 terminal socket, supporting DC input power
    • Lead-acid battery input, reverse polarity protection, and fuse protection
    • Output DC power voltage: -48 V (adjustable from -42 V to -57.6 V)
    • Rated output power: 400 W
    • Alarm monitoring
    • Enabling and disabling of the rectifier module; equalized and float charging for the rectifier module
    • Battery low voltage disconnection; charge and discharge management of storage batteries

    Working Principle

    Figure 1 illustrates the working principle of the H801MPWD board.
    Figure 1 Working principle of the H801MPWD board
    The basic working principle of the H801MPWD board is as follows:

    • AC input power is supplied to the board. After AC/DC conversion, the power is supplied to the system backplane at -48 V (adjustable).
    • The board supports battery input. The monitoring unit manages the charging and discharging of batteries.
    • The board communicates with the system through the backplane, reporting board hardware and electronic label information to the backplane.
    • The board supports communication with the monitoring unit through the 485 protocol to adjust voltage and current and report alarm information.
    • The board supplies 3.3 V power from the system to the monitoring unit.
    • The monitoring unit manages lead-acid batteries.
    • The optical coupler implements the battery low voltage disconnection function.
    • The board provides power distribution checking and alarm reporting functions.

    Panel Description

    Table 1 describes the front panel of the H801MPWD board.
    Table 1 Front panel of the H801MPWD board

    AC IN: AC input LED

    Green: on

    Indicates that the AC input power is normal.

    Off

    Indicates that the AC input power is abnormal.

    DC OUT: DC output LED

    Green: on

    Indicates that the DC output power is normal.

    Off

    Indicates that the DC output power is abnormal.

    BAT: Power input LED

    Green: on

    Indicates that the relay is picked up.

    Off

    Indicates that the relay drops out.

    PMU: Running status LED

    Green: on for 0.25s and off for 0.25s repeatedly

    Indicates that program loading is in progress.

    Green: on for 1s and off for 1s repeatedly

    Indicates that the board runs normally.

    Red: on for 0.25s and off for 0.25s repeatedly

    Indicating that the board is starting up.

    Red: on

    Indicates that a critical alarm is reported.

    Orange: on for 0.25s and off for 0.25s repeatedly

    Indicates that a minor alarm is reported.

    Ports

    The ports of the H801MPWD board are located on its front panel. Table 2 describes the ports of the H801MPWD board.

    Table 2 Table 1-3 Ports of the H801MPWD board

    Port

    Function

    Connection

    AC input port

    Connected to the power socket and used for AC power input

    Cable requirements: low-smoke halogen-free;
    brown for L wire; blue for N wire; yellow green for PE wire

    Battery input port

    Connected through a 3V3 connector and used for battery input

    -

    Port for battery temperature sensor

    Connected to the temperature sensor

    -

    Specifications

    Table 3 lists the specifications of the H801MPWD board.
    Table 3 Specifications of the H801MPWD board

    Board

    Dimensions (W x D x H)

    Power Consumption

    H801MPWD

    • Metric: 35.56 mm x 237.00 mm x 134.84 mm
    • Imperial: 1.4 in. x 9.33 in. x 4.49 in.
    • Static: 2 W
    • Maximum transfer efficiency: 93% (220 V, 100% load, 25°C)